Fluke 117 Electrician's Multimeter with Non-Contact Voltage Detector

The Fluke 117 has the features and functions professional electricians need to get their job done. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The compact design makes it easy to hold and use one-handed. Integrated VoltAlert Technology allows testing for non-contact voltage directly from the meter to help get the job done faster. LoZ technology prevents false readings due to "ghost voltage" and helps accurately diagnose problems. Rely on the Fluke 117 to make your everyday measurements – up to 600 volts ac or dc, 40 MΩ, diode test and exceptionally fast continuity.

 

Fluke 117/322 Shown
Fluke 117/322 Combo Kit Includes:
  • 1 - Fluke 117 TRMS Digital Multimeter with Non-Contact voltage detection
  • 1 - Fluke 322 Compact clamp meter
  • 1 - Fluke TL75 Hard Point Test Lead Set
  • 1 - ToolPak Magnetic Meter hanging Strap
  • 1 -Fluke C115 Deluxe carrying case with shoulder strap

The Fluke Electrician's Combo kit is the perfect solution to meet the demands of Electrical Professionals. This combo kit pairs the new Fluke 117 DMM with a Fluke 322 clamp meter for productive and effective troubleshooting in one total solution, including the new C115 durable soft carrying case for protection and easy meter transportation.

Specifications
Accuracy specifications
Function Range Resolution Accuracy ±
([% of Reading] + [Counts])
DC Millivolts 600.0 mV 0.1 mV 0.5 % + 2
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 2
AC millivolts
true-rms
600.0 mV 0.1 mV 45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
AC volts
true-rms
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
Continuity 600 Ω 1 Ω Beeper on < 20 W, off > 250 W;
detects opens or shorts of 500 µs or longer
Ohms 600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.9% + 2
0.9% + 1
0.9% + 1
0.9% + 1
0.9% + 1
1.5% + 2
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF
10.00 µF
100.0 µF
9999 µF
1 nF
0.01 µF
0.1 µF
1 µF
1.9 % + 2
1.9 % + 2
1.9 % + 2
100 µF to 1000 µF: 1.9 % + 2
> 1000 µF: 5 % + 20
LoZ capacitance (power-up option) 1 nF to 500 µF 10 % + 2 typical
AC amps true-rms
(45 Hz to 500 Hz)
6.000 A
10.00 A
20 A overload for 30 seconds maximum
0.001 A
0.01 A
1.5% + 3
DC amps 6.000 A
10.00 A
20 A overload for 30 seconds maximum
0.001 A
0.01 A
1.0% + 3
Hz (V or A input) 99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1% + 2
Frequency counter sensitivity
Input range Typical sensitivity (rms sine wave)
5 Hz to 45 Hz 45 Hz to 5 kHz 5 kHz to 10 kHz 10 kHz to 50 kHz
Volts AC 6 V
60 V
600 V
0.2 V
2 V
20 V
0.2V to 0.3V
2V to 3V
0V to 30V
0.3 V to 0.4 V
3 V to 4 V
30 V to 40 V
0.4 V to 1.0 V
4 V to 10 V
40 V to 100 V
AC Amps 6 A
10 A
N/A 0.4 A
0.5 A
N/A N/A
Input characteristics
Function Input impedance 
(nominal)
Common mode rejection ratio
(1 kW unbalanced)
Normal mode rejection
Volt AC > 5 MΩ < 100 pF >60dB at dc, 50 or 60Hz -
Volts DC > 10 MΩ < 100 pF >100dB at dc, 50 or 60Hz > 60 dB at 50 or 60Hz
Auto-V LoZ ~3 kΩ < 500 pF > 60dB at dc, 50 or 60Hz -
Ohms Open circuit test voltage Full scale voltage Short circuit current
To 6.0 MΩ To 6.0 MΩ
< 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 µA
Diode Test < 2.7 V dc 2.000 V dc < 1.2 mA
General specifications
Function Description
Maximum voltage
between any
terminal and earth ground
600 V
Surge protection 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2
W Fuse for A input 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec
Temperature Operating: -10°C to +50°C; Storage: -40°C to +60°C
Humidity 0% to 90% to 35°C
75% to 40°C
45% to 50°C
Temperature coefficient 0.1 x (specified accuracy/°C) (< 18°C or > 28°C)
Operating altitude 2,000 meters
Battery 9 Volt Alkaline, NEDA 1604A/IEC 6LR61
Battery life Alkaline: 400 hours typical, without backlight
Safety compliances ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
Certifications UL, CSA, TUV, N10140 , VDE
IP rating
(dust & water protection)
IP42

Location