SEW-Taiwan

SEW New

  • Filter
Created on: 18 February 2014

● Microprocesser-controlled. ● Measures earth resistance in three ranges : 40Ω, 400Ω, 4kΩ.● Capable of measuring earth voltage.● 3 ¾ digit (4000 counts).● LCD backlight display.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Data hold function.● Relative function.● Auto power-off function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS Measuring ranges Earth Resistance 0~40Ω / 0~400Ω / 0~4kΩ Earth Voltage 0~400V (40~500Hz) Accuracy Earth Resistance ±(2%rdg+3dgt) Earth Voltage ±(2%rdg+3dgt) Earth resistanceresolution 0~40Ω : 0.01Ω 0~400Ω : 0.1Ω 0~4kΩ : 1Ω Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Dimensions 163(L) x 102(W) x 50(D)mm Weight (battery included) Approx. 440g  Power source 1.5V (AA) x 6 Safety standards EN 61010-1 CAT IV 400V EN 61326-1 EN 61557-1 EN 61557-5

Created on: 18 February 2014

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Auto power off function.● The timer operates automatically for about three to five minutes   when the "PUSH BUTTON SWITCH" and "TIMER ON BUTTON"   are pressed together. This will keep test "ON" for the duration of the   timer.● Timer for test function (count 3-5 minutes).● Battery operated.● Data hold function.● Small and light weight.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac (40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistanceresolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA. ...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● The leads are supplied as standard accessories for    simplified two-wire measuring system.● 0Ω adjustment. ● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) 0Ω adjustment ˇ Open circuit indication LED will be unlit Low battery indication “  “symbol appears on the display Data hold...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● The leads are supplied as standard accessories for    simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “  “symbol appears on the display Data hold indication ...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● The leads are supplied as standard accessories for    simplified two-wire measuring system.● 0Ω adjustment. ● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) 0Ω adjustment ˇ Open circuit indication LED will be unlit Low battery indication “   “symbol...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without    tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified    two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “  “symbol appears on the display Data hold ...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without    tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified    two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) at 200/2000Ω ±(2%rdg+0.1Ω) at 20Ω Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “   “symbol appears on the display Data hold ...

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.     SPECIFICATIONS       Test voltage (DC V) 2500V  5000V Measuring ranges 0-100GΩ 0-200GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries