Testo Malaysia

Testo 6744 (0555 6744) Dew Point Transmitter with display 1/2 NPT

Category: Transmitters

The Testo 6744 was especially developed for trace humidity measurement in compressed or dry air (e. g. granulate dryers). Thanks to a special adjustment, optimum accuracy in the trace humidity range has been achieved. The result of the development of the testo 6744 is a measuring range of -45 °Ctd to +30 °Ctd and excellent accuracy.

For the display of the relevant trace humidity parameters, the Testo 6744 has a freely scalable analog output is available, optionally with a switch contact plug for MAX monitoring. In addition to this, the 6744 stands out thanks to its compact and user-friendly design, such as the rotatability of the housing by 350° for the optimum positioning of the display.

Functions Specifications
Housing
Dimensions 199.5x37x37 (with standard plug)
203.5x37x37 (with limit signal output plug)
Ambient temperature -20 to 70 °C
Storage temperature -40 to 80 °C
Protection class IP 65
Rotation of housing By 350° (to align display)
Sensor and Sensor Protection
Humidity sensor Testo humidity sensor with protocolled trace humidity adjustment at -40° Ctpd
Temperature sensor NTC
Sensor protection Stainless steel sintered cap
Measurement Range
Pressure dew point temp. (trace humidity) - 60 to +30 °Ctpd
Temperature 0 to 50 °C
Pressure resistance - 1 bar relative to 50 bar
Meas. range of atmospheric dew point 80 to - 15 °Ctd (at 30 bar rel.)
70 to + 10 °Ctd (at 3 bar rel.)
60 to + 30 °Ctd (at 0 bar rel.)
Measurement Inaccuracy
Time constant/damping 0/1/2.5/5/10/20/30/40 sec., can be set by customer, default setting 2.5 s
Humidity +/- 1 K at -10 °Ctpd
+/- 4 K at -40 °Ctpd (each at 25 °C)
Temperature +/- 0.5 K (0 to 50 °C)
Analog Output
Signal 4 to 20 mA, 2 wire technology
Scaling Freely scalable via display/buttons
Standard: 4 to 20 mA = -60 to +30 °Ctpd
Output variables °Ctpd, °Ftpd, °Ctd, °Ftd, %RH, ppmV, mg/m3, °C, °F
Accuracy +/- 40 µA
Power
Voltage 24 VDC (10 to 30 VDC maximum;
20 to 30 VDC with limit signal outputs)
Max. load 10 VDC: 100 Ohm, 30 VDC: 950 Ohm

Location

Ask about this product